Injectune Control software Every value in sight.
Every decision in control.

Select the correct injector profile, follow a guided test sequence and move from live delivery data to a documented result—without leaving the workstation.

Profile-led Live measurement Report ready

DEMOInteractive demo view. This is not identical to the software installed on the machine. Measurements and results are simulated.

Loading software

Preparing your interactive workspace

Software could not load

Reload page
SetupSelect injector profile and named test steps.
5,056 profilesInjectune Control / ReadyDEMOSequence ready05/09/2026, 14:06:41
Profile library
Injector / test preparation0 445 110 183BOSCH / BOSCH 110 / solenoid
Library plan
Injector dossier
ManufacturerBOSCH
Actuationsolenoid
Test fluidunknown
Plan sourceLibrary plan
CodingBOSCH_IMA / IMA
Native stages6 stages
Operating envelope

Conditions across the selected test plan.

Rail pressure
300 - 1700 bar
RPM
1000 - 2500 rpm
Pulse width
0 - 800 us
Injections
1000
Delivery target
0 - 52.9 mm³/st
Return flow
0 - 40 mm³/st
Electrical actuation

Reference data

Force voltage
70 V
Force current
21.75 A
Force time
130 us
Tension current
20 A
Tension time
320 us
Hold current
11.75 A
Off voltage
-48 V
Voltage cap
--
Reference data
Main reference
0 445 110 183
OEM references
FIA 0000071794966; FIA 55197124; FIA 55197875; FIA 71794966; FOR 1538758; FOR 9S519F593BA; LAI 55197124; OPE 93183910; OPE 93190435; VAU 93183910; VAU 93190435
Vehicle / engine
ALFA ROMEO; FIAT; FORD; LANCIA; OPEL; VAUXHALL; MiTo 1.3 JTD; 500 1.3 MultiJet; 500C 1.3 MultiJet; Doblo 1.3 MultiJet; Doblo Cargo 1.3 Mult; Fiorino 1.3 MultiJet; Grande Punto 1.3 Mul; Idea 1.3 MultiJet; Linea 1.3 MultiJet; Panda 1.3 JTD; Punto 1.3 MultiJet; Punto Evo 1.3 MultiJ; Qubo 1.3 MultiJet; Strada 1.3 JTD; Ka 1.3 TDCi; Musa 1.3 MultiJet; Ypsilon 1.3 MultiJet; Agila 1.3 CDTI; Astra 1.3 CDTI; Astra 1.3 CDTI Carav; Astra 1.3 GTC CDTI; Combo 1.3 CDTI; Corsa 1.3 CDTI; Meriva 1.3 CDTI; Astra 1.3 CDTI Estat; Combo 1.3 CDTi; 1.3L 66kW (955); 1.3L 55kW (312); 1.3L 66kW (263); 1.3L 55kW (223); 1.3L 62kW (223); 1.3L 55kW (225); 1.3L 51kW (199); 1.3L 66kW (199); 1.3L 55kW (199); 1.3L 66kW (350); 1.3L 66kW (323); 1.3L 55kW (169); 1.3L 55-56kW (199); 1.3L 55kW (300); 1.3L 63kW (278); 1.3L 55kW (JD); 1.3L 66kW (843); 1.3L 55kW (843); 1.2L 55kW (B); 1.2L 66kW (H); 1.3L 55kW (C); 1.2L 55kW (D); 1.2L 66kW (D); 1.3L 55kW (A); 1.3L 66kW (H); 1.3L 55kW (Tour); 1.3L 55kW (D); 1.3L 66kW (D)
Engine codes
199 A3.000; 169 A1.000; 199 A2.000; 223 A9.000; 199 B2.000; 169 A...; Z 13 DTJ; Z 13 DTH; A 13 DTH; A 13 DTJ
Year range
10/2008 -; 07/2007 - 12/2012; 07/2009 - 12/2012; 02/2010 -; 10/2005 - 08/2016; 10/2005 - 12/2010; 12/2007 -; 07/2008 - 12/2011; 10/2005 - 12/2009; 10/2005 - 12/2011; 11/2004 - 11/2010; 03/2007 -; 05/2006 - 12/2009; 01/2012 - 08/2013; 10/2009 - 12/2011; 09/2008 -; 07/2005 - 12/2011; 09/2008 - 12/2014; 09/2005 - 11/2010; 10/2006 - 11/2011; 10/2006 - 12/2009; 07/2008 -; 08/2005 - 03/2010; 06/2005 - 02/2009; 10/2005 - 01/2012; 07/2006 - 06/2010; 07/2006 - 07/2010; 09/2005 - 09/2006; 10/2006 - 02/2009; 09/2003 - 03/2010; 01/2006 - 03/2010; 06/2005 - 03/2010; 03/2006 - 01/2012; 07/2006 - 03/2009
Notes
Native test plan; Local OEM cross-reference library; Coding BOSCH_IMA/IMA from kt-native-coding-label; requires-measured-acquisition; fyat

Reference information identifies the injector. Test conditions and limits come from the selected plan.

Test planStandard procedureSelect test points. Inspect the conditions before running.
Injector tubes
Test points6/6 enabled
01
02
03
04
05
06
Selected test pointStatic leak
Included
Delivery targetNot evaluated
Return flow40 mm³/stAcceptance limits: 0–80 mm³/st
Measurement count1,000

These conditions and acceptance limits belong to the selected plan. A dash means the plan does not supply that value.

Interface shown for illustrative purposes. Available profiles, coding functions and routines depend on installed configuration.

Select · Test · Verify · Report

One continuous workflow

The interface is organized around the operator's next decision, from profile selection to a documented result.

Select. Test. Verify.
Report.

  1. 01

    Find the profile

    Search the installed databank by injector number, manufacturer or family.

  2. 02

    Verify the setup

    Review the connection, rail pressure and stage conditions before testing.

  3. 03

    Run the sequence

    Use automatic routines or take manual control when the application requires it.

  4. 04

    Read the injector

    Follow delivery, spill, response time and channel status as the test runs.

  5. 05

    Code and match

    Complete supported coding and electronic pairing without losing test context.

  6. 06

    Issue the protocol

    Save or print the technical result for the workshop and customer record.

Coding within context

The code belongs beside the measurement.

Supported coding procedures, response data and injector matching live inside the same operator environment as the test result.

Bosch

IMA · IMA/ISA

Solenoid and piezo injector coding

Delphi

C2i · C3i · C4i

Application-dependent coding workflows

Denso

QR

Solenoid and piezo injector coding

Continental / Siemens

IIC

Piezo injector coding

Configuration note

Available injector profiles, coding functions and test routines depend on the installed database, software version, platform configuration and application-specific fixtures.

Explore the injector profile database or read our guide to injector coding before discussing your application with the team.

Configuration review / Injectune Control

Build around
what you test.

Tell us your injector families, daily volume and required optional coverage. Technical sales will map the platform, fixtures and software scope to your workshop.

Start configuration review

Manufacturer-direct technical sales · Global inquiries

Contact us on WhatsApp